New Gastro+

Gastro + is a handheld gastrolyzer which helps to detect GI (gastrointestinal) disorders by measuring the concentration of hydrogen in the breath. It can be used to help diagnose a variety of gastrointestinal disorders such as, fructose intolerance, lactose intolerance, SIBO, IBS, etc. The test works by hydrogen (H2) is produced when bacteria in the intestine acting on undigested carbohydrates such as lactose and fructose in the small or large intestine. The hydrogen diffuses into the blood and transports to the alveoli in the lungs. With a breath test with Gastro+ the amount of hydrogen can then be detected in the breath.

PROPERTIES:

Gastroplus_small
• Brand new easy to use interface
• Maintenance reminders
• 3 months’ calibration interval
• Create and store patient details
• Multiple patient testing
• Built in testing protocols with built in countdown timer
• Large touch screen
• SteriTouch® technology to kill off harmful bacteria
• Comes with Gastro chart software

SPECIFICATIONS:

IncludedGastrolyzer+, 12 D-Pieces, 250 Steribreath Mouthpieces, GastroChart Software, Carrying case, Manual, 3 x facemasks, facemask sampling kit
Concentration Range (H2)0-500ppm
Sensor sensitivity1ppm
DisplayFull colour touchscreen
H2 cross interference<1%
SensorElectrochemical sensor
SizeApprox. 34 x 75 x 140 mm
WeightApprox. 200 grams including batteries
Alarm10ppm
Batteries3 x AA (LR6 or Equivalent)
1 x CR2032 Lithium coin cell
MouthpiecesSteriBreath and D-Pieces
CalibrationEvery third month with 100ppm H2
Warranty2 years for the instrument and 1 year for the sensor
DatasheetGastro+ (PDF)



GastroCH4ECK

gastrocheckThe GastroCH4ECK™ is a portable breath CH4, H2 and O2 monitor that allows health professionals to accurately detect a range of gastrointestinal disorders such as fructose intolerance, lactose intolerance, SIBO, IBS, etc. An O2 reading is taken to motivate patients into providing an end-tidal sample. If they are unable to do this the GastroCH4ECK™ will automatically correct the reading saving the patient from embarrassment and having to carry out another test. A percentage of patients do not produce hydrogen and therefore would not be diagnosed by the use of HBT alone. Therefore, the role of methane is to ensure that patients who are non-hydrogen producers but produce methane instead are not miss-diagnosed. Medical literature shows that the level of methane producers varies by gender and population group from approximately 33-41%.

PROPERTIES:

• Online breath sampling for instant results.
• Breath bag sampling for simultaneous testing of larger groups.
• Requires calibration just once per month, saving precious time and calibration gas costs.
• Fast warm up time of 30 minutes.
• O2 correction for accurate results.
• Real-time reading graph shown on screen to motivate patients and give instant results.

SPECIFICATIONS:

IncludedGastroCH4ECK Methane & Hydrogen monitor, 50 Mouthpieces or 50 Breath Bags, 1 moisture removal filter, Breath sample line, Calibration Screwdriver, Manual
Concentration rangeCH4: 0-200ppm
H2: 0-200ppm
O2: 14-23%
Power input230V/50Hz/100mA [115V/60Hz/220mA compatible]
SensorsElectrochemical sensor (O2 & H2) Infrared (CH4)
AccuracyCH4: 1ppm
Accuracy: +/-10% of reading
H2: 1ppm
Accuracy: +/-10% of reading
O2: 0,1%
Accuracy: +/-10% of reading
T90 Response Time≤ 45 seconds
DimensionsApprox. 474 x 310 x 167 mm
WeightApprox. 6kg
DisplayFull colour touchscreen
DatasheetGastroCH4ECK (PDF)